Product Type | Rated Current(A) | Crest Current | Minimum Resistance | Size(mm) | Terminals | Drawing Number | ||||
L | L1 | W | W1 | H | ||||||
CDBR-2015 | 15A | 50A | 10Ω | 240 | 228 | 85 | 55 | 153 | M4 | Figure 1 |
CDBR-2022 | 25A | 75A | 6.8Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-2030 | 30A | 85A | 5Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4030 | 15A | 50A | 20Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4045 | 25A | 75A | 13.6Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4055 | 30A | 85A | 12Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4075M | 35A | 100A | 10Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4075 | 35A | 100A | 8Ω | 320 | 304 | 187 | 120 | 163 | M6 | Figure 2 |
CDBR-4110 | 50A | 150A | 6.8Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4160 | 70A | 200A | 5Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4220 | 85A | 300A | 3.3Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4300 | 120A | 400A | 2.5Ω | 320 | 223 | 193 | 304 | 160 | M6 |
In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.
The installation process for an inverter breaker unit can vary depending on the specific unit and the application. However, here are some general steps that can guide you through the process:
Note: This is a general guide, and the specific installation process may vary depending on the unit and application. It is important to follow the manufacturer's instructions and local electrical codes. If you are not familiar with electrical work, it is recommended to seek the assistance of a licensed electrician.
Read the manufacturer's instructions carefully: Before starting the installation, read the manufacturer's instructions and safety precautions carefully. Make sure that you understand the installation process, the wiring requirements, and any other important details.
Choose a suitable location: Choose a location that is suitable for the inverter breaker unit. It should be in a cool, dry, and well-ventilated area, away from direct sunlight, dust, and other contaminants.
Mount the unit: Mount the inverter breaker unit on a suitable surface using appropriate mounting hardware. Make sure that the unit is secure and that there is enough clearance around it for proper ventilation.
Connect the power supply: Connect the power supply wires to the appropriate terminals on the unit. The power supply wires should be sized according to the manufacturer's recommendations and local electrical codes.
Connect the load: Connect the load wires to the appropriate terminals on the unit. Again, the load wires should be sized according to the manufacturer's recommendations and local electrical codes.
Connect the control wires: Connect the control wires to the appropriate terminals on the unit. These wires will be used to control the operation of the inverter breaker unit, such as turning it on and off or adjusting the speed.
Test the unit: Once the installation is complete, test the inverter breaker unit to make sure that it is working properly. Follow the manufacturer's instructions for testing and commissioning the unit.
Maintenance: Regular maintenance of the inverter breaker unit is essential to ensure its continued safe and reliable operation. Follow the manufacturer's instructions for maintenance and inspection of the unit.