Product Type | Rated Current(A) | Crest Current | Minimum Resistance | Size(mm) | Terminals | Drawing Number | ||||
L | L1 | W | W1 | H | ||||||
CDBR-2015 | 15A | 50A | 10Ω | 240 | 228 | 85 | 55 | 153 | M4 | Figure 1 |
CDBR-2022 | 25A | 75A | 6.8Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-2030 | 30A | 85A | 5Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4030 | 15A | 50A | 20Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4045 | 25A | 75A | 13.6Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4055 | 30A | 85A | 12Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4075M | 35A | 100A | 10Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4075 | 35A | 100A | 8Ω | 320 | 304 | 187 | 120 | 163 | M6 | Figure 2 |
CDBR-4110 | 50A | 150A | 6.8Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4160 | 70A | 200A | 5Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4220 | 85A | 300A | 3.3Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4300 | 120A | 400A | 2.5Ω | 320 | 223 | 193 | 304 | 160 | M6 |
In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.
Repairing an inverter breaker unit can be a complex task and should only be attempted by qualified professionals with proper training and experience in electrical and electronic equipment repair. However, here are some general steps that may be followed for repairing an inverter breaker unit:
Identify the problem: Before attempting any repairs, you should identify the specific problem with the inverter breaker unit. This may involve using diagnostic tools such as multimeters, oscilloscopes, or other testing equipment.
Disconnect power: Make sure that the inverter breaker unit is disconnected from the power source before attempting any repairs. This is to prevent electrocution or damage to the unit.
Remove the cover: Depending on the specific model of the inverter breaker unit, you may need to remove the cover to access the internal components. Follow the manufacturer's instructions for removing the cover.
Inspect for damage: Inspect the internal components of the inverter breaker unit for any signs of damage, such as burnt or swollen capacitors, broken wires, or damaged circuit boards.
Replace damaged components: If any components are found to be damaged, they should be replaced with new ones. Make sure to use components that are rated for the same voltage and current as the original ones.
Test the unit: After repairing the inverter breaker unit, test it to ensure that it is working properly. This may involve connecting it to a power source and using diagnostic tools to check for proper voltage and current levels.
It is important to note that the specific steps for repairing an inverter breaker unit may vary depending on the model and manufacturer. It is recommended to consult the manufacturer's instructions or seek the assistance of a qualified professional for proper repairs.