Product features
RS485 Communication Controlling Type Stepper Drive
![]()
Strong compatibility and scalability
It is compatible with pulse signal input and I/O internal control mode. One drive is with multiple functions bringing more expansion possibilities, greatly reducing system costs.
![]()
RS485 Communication
With RS485 communication connection, based on standard ModbusRTU protocol, it can support multi-axis RS485 motion control network.
![]()
DE series pulse type closed-loop driver
"Closed-loop stepper" drive system is the innovative integration of closed-loop control technology into the stepper motor by Division according to market demand and prospects, creating a new A drive for performance. Successfu-lly solved the problems of dislocation and lost steps of the traditional stepping system, and further improved the sp-eed and acceleration of the stepping motor can effectively reduce the cost of equipment use. Closed-loop stepping not only has the same motor installation size as traditional stepping 28/36/42/57/60/86/110/130mm, etc., but also Simple and easy to set up, the performance is improved by more than 50% compared with the traditional stepping, and the price is less than half of the AC servo. It is the first choice for medium and low speed servo applications!
![]()
EtherCAT FieId Bus CIosed Loop Step Drive
![]()
Product Overview
EtherCAT series bus-type stepper products are bus-type stepper drivers that add bus communication function on the basis of the original high-voltage pulse-type stepper drivers. Pick Using the EtherCAT bus communication inte-rface, based on the EtherCAT slave technology, the transmission rate of 100Mb/s realizes the real-time control and real-time data transmission of the servo system. only Support CSP, HM operation mode. The driving voltage is AC200V~240V, and it is suitable for various types of three-phase hybrid stepper with current below 7.0A and outer diameter of 86~130mm.into the motor. Compared with the traditional pulse servo driver, the driver is especially suitable for applications in long-distance, multi-axis linkage applications, such as manipulators, packaging machi-nery, etc.The wiring can be greatly reduced and the reliability of the drive operation can be enhanced.
![]()
Bus-type closed-loop stepper driver
![]()
EtherCAT series bus-type closed-loop stepping products are bus-type closed-loop stepping products that add bus communication function on the basis of DE series high-performance stepping closed-loop drivers.drive. Using the EtherCAT bus communication interface, based on the EtherCAT slave technology, the transmission rate of 100Mb /s realizes the real-time control and real-time data of the stepping system transmission. It has the advantages of high performance, high transmission speed and high reliability communication. EtherCAT series can drive 20/28/ 42/57/60/86 and other flange frame closed-loop stepping motor. The driver has abundant input and output interfa-ces and supports CSP, PP, and HM operating modes. Compared to conventional pulsed drives, this drive is parti-cularly suitable for It can greatly reduce the wiring and enhance the reliability of the drive operation.
![]()
![]()
![]()
![]()
![]()
In the trend of advocating smart and simple industrial automation, environmentally friendly products, value-added solutions, K-Drive, as one of the world's leading drive manufacturers aggressively investing in R&D, production, and continuous quality improvement, is well positioned to provide its customers with technology-driven, performance-outstanding products such as VFDs, wind power converters, servo drives, HEV/EV drives, helping its customers save energy and increase industrial productivity with sustainability on the one hand, and enhancing their entire value-chain quality, delivery, and services on the other hand.
In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.
![]()
| Performance | Common brands | K-Drive |
|---|---|---|
| Applicable motors | Asynchronous motors | Asynchronous /synchronous motors |
| Starting torque | 2.0Hz, 150% (sensor-less vector control) 0Hz, 180% (closed-loop vector control) | 0.5Hz, 180% (sensor-less vector control) 0Hz, 200% (closed-loop vector control) |
| Speed adjustable range | 1:100 (SVC), 1:1000 (VC) | 1:200 (SVC), 1:1000 (VC) |
| Ambient temperature (no derating required) | -10-40ºC | -10-50ºC (for most of the models) |
| Rated input voltage | 208VAC-400VAC | 208VAC-480VAC |
| Communication | Modbus RTU//ASCII | Modbus RTU//ASCII Profibus-DP, CANopen, etc. |
| Position control (fixed length, or angular positioning) | × | √ |
| Field weakening control | × | √ |
| Autotune online | Online | Online & Offline |
| Short-time ramp-up | Trip | No trip |
| Customized features (software and/or hardware) | Unprocurable or no experience |
Procurable with rich experience |
When selecting a stepper motor, there are several factors to consider:
Torque: The torque required to drive the load must be considered, and the stepper motor selected should be able to deliver sufficient torque to move the load.
Speed: The speed at which the motor needs to operate must also be considered. Stepper motors have a maximum speed at which they can operate, and if the required speed exceeds this limit, a different type of motor may be needed.
Size: The size of the motor should also be considered, as it should be able to fit into the available space.
Resolution: Stepper motors have a specific number of steps per revolution, which determines the motor's resolution. The resolution required will depend on the application.
Power supply: The voltage and current requirements of the motor should be considered to ensure that the power supply can meet the motor's requirements.
Environmental factors: The operating environment, including temperature, humidity, and vibration, should be considered when selecting a stepper motor.
Controller: The type of controller required should also be considered, as different controllers may be needed depending on the application.
By taking these factors into consideration, you can select a stepper motor that meets the requirements of your application.