Model | Power Rating | Input Voltage | Output FREQ | Type |
---|---|---|---|---|
KD600 Series | 0.4kW-900kW | 690V ±10% | 0.00-3200.00Hz | DC/AC to AC inverters |
Thanks to sophisticated engineers, scientific producing workmanship, rigorous quality control systems and management team, K-Drive frequency inverters are equipped with advanced features, some of which are listed as below:
01. Starting torque: 180% at 0.5Hz (V/f pattern, SVC pattern);
02. Speed adjustable range: 1: 100 (V/f pattern, SVC pattern);
03. Speed accuracy: +/-0.5% (V/f pattern), +/-0.2% (SVC pattern);
04. Over load capability: 150% 1minute, 180% 10seconds;
05. Abundant frequency command sources;
06. Diverse input and output terminals;
07. Ambient temperature: -10°C~50°C;
08. High precise torque constraint, process PID control, multi-speed control, contracting brake control, field weakening control, all sides protection, etc;
09. Online and offline auto-tuning of motor parameters can both performed;
10. Extremely short-time acceleration can be performed without any trip, such as 0.1s or 0s from 0Hz to 50Hz;
Mains Supply (L1/L,L2,L3/N) | |
---|---|
Supply voltage | 208-240V ±10% 380-480V 690V ±10% |
Power source frequency | 50/60Hz ± 5% |
Displacement power factor (cos φ) | (>0.98) |
Output Data (U, V, W) | |
---|---|
Output voltage / frequency | 0-100% of supply voltage / 0.00-600.00Hz or customized |
Ramp time | 0.01-60000s |
Note: 150% current can be provided for 1 minute, 180% for 10 seconds. Higher overload rating is achieved by oversizing the drive.
Digital Input | |
---|---|
Programmable digital inputs | 5 |
Logic | NPN or PNP |
Voltage level | 22 - 26V |
Analog Input | |
Analog inputs | 2 |
Modes | Voltage or current |
Level | 0 to +10V, 0/4 to 20 mA (scalable) |
Automatic correction | YES |
Relay Output | |
Programmable relay outputs | 1 |
RA - RB / TA - TB | Normally close |
RA - RC / TA - TC | Normally open |
Contact capacitance | 250 V AC / 3A, 30 V DC / 3 A |
Terminal 485 Interface | |
485+ / 485- | Rate: 4800/9600/19200/38400/57600/115200 bps Max. distance: 500 m |
GND | Isolated from COM |
Ambient | |
Vibration | Less than 5.9 m/s² (0.6g) |
Humidity | Relative humidity 5% - 95 %. No condensation |
Corrosive environment | 3C3 |
Ambient temperature | -10 ºC - 50 ºC |
Altitude | 0 - 2,000 m |
Rated output current derated 1% every 100 m above 1,000 m | |
Storage temperature | -40 - +70 ºC |
Efficiency | Efficiency At rated amps: ≥93% |
IP grade | IP20 |
Cooling method | Forced air cooling |
Fieldbus Communication | |
Modbus RTU, Modbus ASCII | Built-in |
KD600 drives are economical series at K-Drive. They offer V/f control, including voltage and frequency separated control, adaptable to various industrial applications if sensor-less vector control is not required, including printing machines, packaging machines, pumps, fans and blowers, etc.
Conveyors | Centrifuges | Food processing Machinery |
Pumps | Fans | More … |
In the trend of advocating smart and simple industrial automation, environmentally friendly products, value-added solutions, K-Drive, as one of the world's leading drive manufacturers aggressively investing in R&D, production, and continuous quality improvement, is well positioned to provide its customers with technology-driven, performance-outstanding products such as VFDs, wind power converters, servo drives, HEV/EV drives, helping its customers save energy and increase industrial productivity with sustainability on the one hand, and enhancing their entire value-chain quality, delivery, and services on the other hand.
In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.
Performance | Common brands | K-Drive |
---|---|---|
Applicable motors | Asynchronous motors | Asynchronous /synchronous motors |
Starting torque | 2.0Hz, 150% (sensor-less vector control) 0Hz, 180% (closed-loop vector control) | 0.5Hz, 180% (sensor-less vector control) 0Hz, 200% (closed-loop vector control) |
Speed adjustable range | 1:100 (SVC), 1:1000 (VC) | 1:200 (SVC), 1:1000 (VC) |
Ambient temperature (no derating required) | -10-40ºC | -10-50ºC (for most of the models) |
Rated input voltage | 208VAC-400VAC | 208VAC-480VAC |
Communication | Modbus RTU//ASCII | Modbus RTU//ASCII Profibus-DP, CANopen, etc. |
Position control (fixed length, or angular positioning) | × | √ |
Field weakening control | × | √ |
Autotune online | Online | Online & Offline |
Short-time ramp-up | Trip | No trip |
Customized features (software and/or hardware) | Unprocurable or no experience | Procurable with rich experience |
All drives are well packed before shipment, fit for air shipment, sea transportation, and express delivery. Customers are able to call its own nominated forwarder or consult K-Drive logistics department for worldwide shipment services.
* Low-power inverters are packed in cardboard box, and others are in plywood cases.
* Plenty of transportation procurable globally in accordance with customer demand or K-Drive expertise.
Please leave us an inquiry for more details of our frequency inverters, like information of the model numbers, technical data, applicable application, pricing, distributor policy, lead time and/or customized functionality.
Assuming you're referring to an air conditioning system, the following are some general tips for maintaining an AC unit:
Clean or replace the air filter: The air filter in your AC unit collects dust, dirt, and other particles over time, which can restrict airflow and decrease the unit's efficiency. Clean or replace the filter regularly, ideally once a month.
Clean the evaporator and condenser coils: The evaporator and condenser coils can also accumulate dirt and debris, which can reduce the AC's efficiency. Clean them periodically using a soft brush or a vacuum cleaner.
Check the refrigerant levels: The refrigerant is what cools the air in your AC unit, and if the levels are too low, the unit won't work as efficiently. Have a professional technician check the refrigerant levels and recharge the system if necessary.
Check and clean the condensate drain: The condensate drain removes excess moisture from the air, but it can become clogged with dirt or debris. Check the drain periodically and clean it if necessary to prevent water damage or mold growth.
Schedule regular maintenance: To ensure your AC unit is in good working condition, have it serviced by a professional technician once a year. They can identify and fix any issues before they become major problems and ensure your unit is running at peak efficiency.
By following these tips, you can help prolong the life of your AC unit and keep it running smoothly.